Remove a fractured screw without damaging the fixture

Surgical drills and fixture drivers for fixture implantation are included.

Improvement of fixation and increase clinician’s comfort when placing implants by widening cutting edge area 2 times compared to IS-II Active.

Perfect Guide and Conical, Internal, External Guide act as the guide when using the reverse drill.

Make a precision hole to connect the screw remover without damaging internal screw thread of implant.

Capable to remove fractured screws from different implant system.

Surgical drills and fixture drivers for fixture implantation are included.

Improvement of fixation and increase clinician’s comfort when placing implants by widening cutting edge area 2 times compared to IS-II Active.

SR Kit is equipped with reverse drill and guide of various sizes.

Available from M1.8 to M2.5 of screw hole size

1.Claw

Length(mm) / Product name
Fractured Screw size
Product name
M1.6
CD16
M1.8
CD18
M2.0
CD20
M2.5
CD22

2.Reverse Drill

Length(mm) / Product name
Fractured Screw size
Hex
Product name
M1.8
Ø1.0
RCD10
M2.0
Ø1.2
RCD12
M2.5
Ø1.4
RCD14
*For M1.6 size screw, use the claw for removal (2,000rpm)

3.Screw Remover

Length(mm) / Product name
Fractured Screw size
Hex
Product name
M1.8
Ø1.0
SR10
M2.0
Ø1.2
SR12
M2.5
Ø1.4
SR14
*For M1.6 size screw, use the claw for removal (2,000rpm)

4.Shank Driver

Length(mm) / Product name
Applicable Products
Standard
Product name
Screw Remover(SR10, SR12, SR14)
for Hand or Ratchet
SHD00

5-1.Perfect Guide & PG Hand Driver

Perfect Guide
Fractured Screw Size
Diameter
Product name
M1.8
Ø1.0
PG1018
M1.8, M2.0
Ø1.2
PG1220
M2.0, M2.5
Ø1.4
PG1425

5-2.Perfect Guide & PG Hand Driver

PG Hand Driver
Applicable Products
Standard
Product name
Screw Remover(SR10, SR12, SR14)
2.5Hex
PGHD25SS

6-1.Conical, Internal, External Guide

Conical Guide
Product name
Standard
Applicable fixture
CG00
11˚/ 8˚
Having 11˚/ 8˚ Internal Fixture

6-2.Conical, Internal, External Guide

Internal Guide
Product name
Standard
Applicable fixture
IHG24
2.4Hex
Having 2.4Hex Internal Connection Fixture
CG00
2.5Hex
Having 2.5Hex Internal Connection Fixture
CG00
3.1Octa
Having 3.1Octa Internal Connection Fixture

6-3.Conical, Internal, External Guide

External Guide
Product name
Standard
Applicable fixture
EHG24
2.4Hex
Having 2.4Hex Internal Connection Fixture
EHG27
2.7Hex
Having 2.7Hex Internal Connection Fixture
EHG34
3.4Hex
Having 3.4hex Internal Connection Fixture

7.SR Driver Holder

PG Hand Driver
Product name
Standard
Product name
GH00
2.4Hex
Conical Guide: CG00
GH00
2.4Hex
Internal Guide: IHG24, IHG25, IOG31
GH00
2.4Hex
External Guide: EHG24, EHG27, EHG34

Crestal approach

1
Failed Implant
  • Completely remove the prosthesis of the implant that needs to be removed.

2
Perfect Guide
  • Select an appropriate size of Perfect Guide.

  • By using the PG Hand Driver, tighten the Perfect Guide To the fixture in a clockwise direction until it touches the screw inside the fixture.

3
Reverse Drill
  • Select an appropriate size of Reverse Drill and connect it to the contra angle of the surgical engine.

  • Insert the Reverse Drill into the Perfect Guide attached on the fixture.

  • By drilling counter clockwise at a speed of approximately 2,000rpm, drill 1~2mm into the surface of the fractured screw.

  • Check the marking line(in 1mm intervals) of the drill body while drilling with adequate irrigation.

4
Screw Remover