RidgeWider Kit
The ultimate ridge splitting solution in narrow alveolar ridge.
Introduction
|
The Safe Disk and Bone Expander from the Ridge Wider Kit enable safe and effective horizontal expansion and simultaneous implant placement in narrow ridges.
|
|
| 1. Bone Trimmer Used to flatten and smooth out the narrow alveolar crest
- Side blades enable quick trimming of the alveolar crest - 1,200 rpm
|
|
| 2. Ø1.5 Initial Drill Used for initial drilling before bone expansion
|
|
|
3. Stopper
- Stoppers for the Ø1.5 Initial Drill
|
|
| 4. Safe Disk Used for cutting across the narrow ridge 1) Non-Saw Type - Disk-type blade for maximum safety - Improved cutting performance through diamond powder coating - 1,200 rpm 2) Saw Type (optional) - Saw-type blade with greater cutting performance (for experienced users) |
|
| 5. Bone Chisel Used for initial ridge expansion
- Slight expansion of the ridge through inserting the Chisel between the cortical plates - Additionally separates the attached remaining bone - 3 / 5 / 7mm
|
|
| 6. Bone Expander Used for sequential bone expansion
- Gradual bone expansion of the initially drilled receptor site |
|
| 7. Ratchet Connector Connects Torque Ratchet and Bone Expander
|
|
| ▼ |
|
1. Narrow Ridge Case Identify the narrow ridge case that is difficult to place implant
|
|
| ▼ |
|
2. Trimming Bone Use the Bone Trimmer to flatten and trim the narrow ridge where the implants would be placed (Recommended rpm : 1,200)
|
|
|
▼ |
|
3. Initial Drilling
|
|
|
▼ |
|
4. Vertical Sawing
|
|
|
▼ |
|
5. Buccal Sawing Vertically cut the buccal side with the Safe Disk (Recommended rpm : 1,200~2,000) ※ If necessary, you may cut the mesial and distal side of the cortical bone with the Safe Disk (for buccal cutting use Ø7.0mm, T1.0mm Safe Disk)
Horizontally cut the lower part of the buccal side with the Safe Disk (Recommended rpm : 1,200~2,000) ※ If necessary, you may cut the the lower cortical bone with the Safe Disk (for buccal cutting use Ø7.0mm, T1.0mm Safe Disk) |
|
|
▼ |
|
6. Initial Expansion Insert the Bone Chisel between the cutted space to split and expand the ridge. |
|
|
▼ |
|
7. Sequential Bone Expanding Gradually expand the ridge by sequentially inserting the Bone Expander up to the fixture size (Recommended rpm : 25~35)
※ In the case of Ø3.5 fixture, use Bone Expander up to Ø3.0 if necessary (for placing implant in the posterior region, fixture diameter larger than Ø4.5 is recommended) |
|
| ▼ |
| 8. Implant Placement ImplantPlace the fixture in to the expanded alveolar bone
|
|
| ▼ |
|
9. Connect Cover Screw the Cover Screw to the placed implant using the 1.2 Hex Driver
|
|
| ▼ |
|
10. Application of graft material Graft bone in the expanded space after implant placement. (Optional) |
|
|
|
|
11. Complete |
![]() |
|